RH28
TSO'd REGULATED DC-DC POWER CONVERTER
(14 to 28Vdc High Power DC Converter)
The KGS model RH28 converts 14 Vdc input voltage to a regulated 28 Vdc output voltage. The converter is capable of delivering 280 Watts continuously at 28 Vdc and up to 10 amperes output.
DESCRIPTION
A state of the art "Synchronous Current Mode Switching" topology with Surface Mount Technology (SMT) is used to realize the power conversion. Control circuitry includes use of a popular Synchronous PWM controller for voltage regulation and overload current limit. Because of the design topology, a wide input voltage range is possible while delivering highly regulated 28Vdc output power.
Specifications
Input Voltage
Normal: 12 to 28 Vdc
Abnormal: 8 to 36Vdc
Normal: 12 to 28 Vdc
Abnormal: 8 to 36Vdc
Input Current
21.8 Amps typ at 14 Vdc input &@FL
(0.5 Amps maximum at no load)
21.8 Amps typ at 14 Vdc input &@FL
(0.5 Amps maximum at no load)
Overload
Unit will not suffer damage or degradation in performance from an overload input current of 50 Amps for 5 Sec or until a 25 Amp input circuit beaker trips
Unit will not suffer damage or degradation in performance from an overload input current of 50 Amps for 5 Sec or until a 25 Amp input circuit beaker trips
Output Voltage
28 ± 0.5 Vdc regulated for input voltage from 8 to 28 Vdc (Switching Mode)
Follows input voltage for the input above 28 Vdc (Override Mode)
28 ± 0.5 Vdc regulated for input voltage from 8 to 28 Vdc (Switching Mode)
Follows input voltage for the input above 28 Vdc (Override Mode)
Output Current
0-10 Amps continuous.
15 amps for 5 minute.
0-10 Amps continuous.
15 amps for 5 minute.
Power
280 Watts continuous for input voltage from 12 to 28 Vdc.
420 Watts for 5 minutes at 14 Vdc input voltage
280 Watts continuous for input voltage from 12 to 28 Vdc.
420 Watts for 5 minutes at 14 Vdc input voltage
Regulation
1% for line, 1% for load and 1% for temperature
1% for line, 1% for load and 1% for temperature
Overload (OL)
Delivers 110% output power for 2 hours minimum
Delivers 110% output power for 2 hours minimum
Protection (OL):
Withstands without damage or degradation, loads exceeding 110% of the rated current. Output voltage falls toward input voltage when load exceeds 20 Amps. Unit delivers rated output power upon removal of the overload (OL) conditions.
Withstands without damage or degradation, loads exceeding 110% of the rated current. Output voltage falls toward input voltage when load exceeds 20 Amps. Unit delivers rated output power upon removal of the overload (OL) conditions.
Protection (SC)
Unit is protected against output short circuit by an external 25 Amp input circuit breaker per MIL-C-5809
Unit is protected against output short circuit by an external 25 Amp input circuit breaker per MIL-C-5809
Efficiency
92% typical
92% typical
Temperature
-55° C to +71° C
-55° C to +71° C
Altitude
55,000FT
55,000FT
Compliance
FAA TSO-C71
FAA TSO-C71
Environmental:
DO-160D/C test, design similarity and/or design analysis:
F2-BBB[STX]EWXDFSABAZZXLXXXX
DO-160D/C test, design similarity and/or design analysis:
F2-BBB[STX]EWXDFSABAZZXLXXXX
Weight:
1.3 lbs.
1.3 lbs.
Size
2.75 W x 6.875 L x 2.24 H inches Less protrusion of connector
69.9 W x 174.6 L x 56.9 H mm and screw heads
2.75 W x 6.875 L x 2.24 H inches Less protrusion of connector
69.9 W x 174.6 L x 56.9 H mm and screw heads
Cooling
Convection and thermal conduction through the bottom plate (No internal fan)
Convection and thermal conduction through the bottom plate (No internal fan)
Finish
Gold iridite per MIL-C-5541 Class 1A
Gold iridite per MIL-C-5541 Class 1A