TSO'd 350VA REGULATED POWER INVERTER
0-115V/400Hz Electroluminescent Lamp Power Supply
The SD35 is a pulse width modulated DC to AC converter that provides regulated 0 to 115 Vac power up to 3.04 amperes for EL panel lighting. The SD35 will power approximately 2000 in² to 2600 in² area of a EL panel.
The output voltage is varied by a slider voltage 0-5 Vdc applied at pin F from a remote control potentiometer 5K ohm 1/2 watt to ground or directly from a 0-5 Vdc source.
An internal trim pot is provided to adjust the output voltage ±10% at its full clockwise position of the external pot.
Circuit protection includes low input voltage shutdown, soft start, high input voltage shutdown, output over voltage limit and output short circuit current limit.
Specifications: | |
Input Voltage: | 28 Vdc NOM., 24 to 32 Vdc |
18 Vdc to 36.4 Vdc (Abnormal Range) | |
Input Current: | 6.7 Amps typ at 350VA EL load at 28V |
2.8 Amps maximum at no load | |
Output Voltage: | 0-115 Vac regulated |
Output Current: | 0-3.04 Amps continuous |
Power: | 350 VA maximum for EL panel |
Power Factor: | Zero to -0.2 leading (capacitive) |
Frequency: | 400 Hz ±2% |
Distortion: | 5% typ at 28 Vdc for 350VA, -.2pf load |
Regulation: | 5% for load, 3% for line and 3% for temperature |
Control: | Output voltage 0-115 Vac is controlled by an external 5 K potentiometer or a 0-5 Vdc source applied at pin F. |
Isolation: | Output is isolated from input |
Overload(OL): | Deliver 150% output power for 5 min. |
Protection(OL): | Withstands without damage or degradation load exceeding 150% (-.2pf) to an output short circuit. Unit delivers rated output power upon removal of the overload condition. |
Protection(SC): | Under a output short circuit condition, the input current folds back and the output current is limited to a safe value. |
Protection(OV): | Output voltage is limited to 145 Vac maximum |
Soft-Start: | Minimum soft start delay of 100 mSec at full load is provided during an application of step input. |
Shutdown(SD): | Output shuts down when input voltage is below 14 Vdc and above 36.4 Vdc. |
Temperature: | -55°C to +71 °C |
Altitude: | 55,000FT |
Connector: | Mates with MS3106A18-9S |
Finish: | Gold iridite per MIL-C-5541 Class 1 A |
Weight: | 5.3 LBS (2.4 kg) |
Size: | 3.45 H x 8.25 W x 3.45 L inches |
113.0 H x 209.5 W x 87.6 L mm | |
Less protrusion of connector and screw heads |
Outline Drawing | External Wiring
SD3
TSO'd REGULATED E/L PANEL INVERTER
0-115 Vac Electroluminescent Lamp Power Supply
Outline Drawing | External Wiring
FD15
REGULATED AC POWER CONVERTER
115V/400Hz to 0-115V/400Hz Electroluminescent Lamp Power Supply
Outline Drawing | External Wiring
FJ20
AC TO AC POWER CONVERTER
115V/400Hz to 0-5V/400Hz 200VA Light Dimming Power Supply
Outline Drawing | External Wiring
SD35
TSO'd 350VA REGULATED POWER INVERTER
0-115V/400Hz Electroluminescent Lamp Power Supply
Outline Drawing | External Wiring
AC TO AC POWER CONVERTER
115V/400Hz to 0-5V/400Hz 200VA Light Dimming Power Supply
The FJ20 is a pulse width modulated AC to AC power converter that provides regulated 0 to 5 Vac 400 Hz power up to 40 amperes. The output voltage is controlled by a slider voltage 0-5 Vdc applied at pin M from a potentiometer 10K ohm 1/2 watt to ground or directly from a 0-5 Vdc source applied at pin M.
An internal trim pot is provided to adjust the output voltage ±10% at its full clockwise position of the external pot.
Circuit protection includes low input voltage shutdown, soft start, high input voltage shutdown, output over voltage limit and output short circuit current limit.
Specifications: | |
Input Voltage: | 115 Vac 400 Hz nom., 105 to 125 Vac |
95 Vac to 130 Vac (Abnormal Range) | |
Input Current: | 2.8 Amps typ @ FL & at 115 V input |
Output Voltage: | 0-5 Vac 400 Hz regulated |
Output Current: | 0-40 Amps continuous |
Frequency: | 400 Hz ± 2% |
Distortion (THD): | 7% max at full load & at 115 Vac input |
Power: | 200 Watts |
Power Factor: | Unity (resistive) |
Overload( OL): | 150% output current for 5 min. |
Protection (OL): | Withstands without damage or degradation load exceeding 150% to an output short circuit. Unit delivers rated output power upon removal of the overload condition |
Regulation: | 7% for load, 2% for line and 3% for temperature |
Isolation: | Output is isolated from input |
Control: | Output 0-5 Vac is controlled by a 0-5 Vdc voltage from the slider of an external 10K ohm pot or directly from a 0-5 Vdc voltage source |
Protection (SC): | Under a output short circuit condition, the input current folds back and the output current is limited to a safe value |
Protection (OV): | Output voltage is limited to 145 Vac maximum |
Soft-Start: | Minimum soft start delay of 100 mSec at full load is provided during an application of step input voltage to reduce output in rush current to the load. |
Shutdown (SD): | Output shuts down when input voltage is below 95(±10) Vac and above 135(±10) Vac |
Temperature: | -55°C to +71 °C |
Altitude: | 55,000FT |
Connector: | Mates with MS3106A28-9S |
Finish: | Gold iridite per MIL-C-5541 Class 1A |
Weight: | 5.3 LBS (2.4 kg) |
Size: | 4.60 H x 4.42 W x 6.47 L inches |
116.8H x 112.3 W x 164.3 L mm | |
Less protrusion of connector and screw heads |