TSO’d 30 VA STATIC INVERTER (28 Vdc to 400Hz Sinewave)
DESCRIPTION
The SC3 & SC3(A) are pulse width modulated dc to ac static inverters that provide regulated 400 Hz AC power up to 30 volt amperes.
An internal trim pot is provided to adjust the output voltage ± 10%
Circuit protection includes low input voltage shutdown, soft start, high input voltage shutdown, output over voltage limit and output short circuit current limit
3% typical at FL (unity pf) at 28 Vdc 7% maximum for the input range & pf
Isolation:
Output is isolated from input
Power
30 VA maximum
Power Factor:
.95 leading to .8 lagging power factor
Regulation:
3% for load, 2% for line and 3% for temperature
Overload(OL):
Deliver 150% output current for 5 min.
Protection(OL):
Withstands without damage or degradation load exceeding 150% to an output short circuit. Unit delivers rated output power upon removal of the overload condition
Protection(SC):
Under a output short circuit condition, the input current folds back and the output current is limited to a safe value
Protection(OV):
Output voltage is limited to 145 Vac maximum
Soft-Start:
Minimum soft start delay of 100 mSec at full load is provided during an application of step input voltage to reduce output in rush current.
Shutdown(SD):
Output shuts down when input voltage is below 14 Vdc and above 36.4 Vdc.
Temperature:
-55° C to +71° C
Altitude:
55,000FT
Compliance:
FAA TSO-C73
Connector:
Unit mates with MS3106A14-6S
Finish:
Gold iridite per MIL-C-5541 Class 1A
Weight:
1 LBS (454 grams)
Size:
2.00 H x 3.18 W x 5.00 L inches 50.8 H x 80.8 W x 127.0 L mm (Less protrusion of connector and screw heads)