| Specifications: |
| Input Voltage: |
115 VAC ± 15 VAC |
| Input Frequency: |
50/60 Hz |
| Input Phase: |
Single |
| Input Protection: |
- Protected from input overvoltage (unit will shut itself off above 135
VAC)
- Protected from over current with 15 amp circuit breaker. This circuit
breaker is also used for the input power on-off switch.
|
| Output Voltage*: |
115 VAC (100 to 125VAC adjustable) 26 VAC
(22.6 to 28.2VAC adjustable) |
| Output Power: |
115 VAC out . 750 VA |
| |
26 VAC out . 500 VA |
| |
Total output power 750 VA |
| Output Frequency*: |
400 Hz (380 to 420 Hz adjustable) |
| Phase: |
Single |
| Wave: |
Sine |
| Amplitude Distortion: |
2% Typical |
| Power Factor: |
.8 to -.95. |
| Overload: |
Delivers 150% current for at least 5 minute.
Withstand short circuit for 1 minute minimum. |
| Protection: |
- Unit will shut off under the following: output frequency below 375 Hz or
above 425 Hz, output voltage above 130 VAC.
- Unit will trigger audible warning 130% above rated load.
|
| Temperature: |
-40°C to +71 °C |
| Weight: |
32 lbs. |
| Size: |
17"W x 13"D x 7"H for 19"
relay rack. |
| Cooling: |
Internal fan, thermostatically controlled. |
| Connections: |
5 way binding posts for front panel
connection. 6-32 terminal block for rear panel connection. |
| * Adjusted from front panel. |
|