Specifications: |
| Input Voltage: |
115 VAC ± 15 VAC |
| Input Frequency: |
50/60 Hz |
| Input Phase: |
Single |
| Input Protection: |
Protected from input overvoltage (unit will shut itself
off above 135 VAC). Protected from overcurrent with 20 amp. circuit breaker. This circuit
breaker is also used for the input power on-off. |
| Output Voltage*: |
- 115/200 VA (100 to 125 VAC L-N) adjustable
- 115/200 VA (173 to 216 VAC L-L) adjustable
- 26/45 VA (22.6 to 28.2 VAC L-N) adjustable
- 26/45 VA (39.1 to 48.8 VAC L-L) adjustable
|
| Output Power: |
- 115 VAC ...1000 VA Total (330 VA / phase)
- 26 VAC ... 225 VA Total (75 VA / phase)
|
| Output Frequency*: |
400 Hz (380 to 420 Hz) adjustable |
| Phase: |
3 Phase |
| Wave: |
Sine |
| Amplitude Distortion: |
2% T. H. D. typical |
| Power Factor: |
.8 to -.95 |
| Overload: |
Delivers 150% overload for at least 5 minutes.
Withstands short circuit for 1 minute minimum. |
| Temperature: |
-40°C to +71°C |
| Weight: |
35 lbs. |
| Cooling: |
Internal fan thermosatically controlled. |
| Protection: |
Unit will shut itself off under the following
conditions:
- Under frequency (below 375 Hz).
- Over frequency (above 425 Hz).
- Over voltage (above 130 VAC).
|
| Connections: |
Front panel mating connector: MS3106A24-11P
Rear panel 6-32 Terminal block. |
| Size: |
17"W x 13"D x 7"H for 19" relay rack
mounting. |