Specifications: |
| Input Voltage: |
Nominal; 28.0 VDC ± 4 VDC, Range: 20 to 37 VDC |
| Input Current: |
32A @ full load, 3A max @ no load |
| Output Voltage: |
+5% -7% (± 2% typ. on 115V) |
| Output #1: |
115 VAC (750 VA max. cont.) |
| Output #2: |
26 VAC (150 VA max. cont.) |
| Output #3: |
5 VAC (30 VA max. cont.) |
| Output Power: |
750 VA Total max. |
| Output Frequency: |
400Hz ± 1% |
| Phase & Waveform: |
Single phase sine wave. |
| Harmonic Distortion: |
2.0% typ. (5% max.) 20 to 37 VDC in. |
| Power Factor: |
.8 to -.95 |
| Efficiency : |
83% typical. |
| Temperature: |
-55°C to 71°C |
| Weight: |
14.0 lbs. |
| Overload Capacity: |
Capable of 150% output current @ normal AC output for 5
minutes. |
| Input Overvoltage: |
Withstand 130% input overvoltage for 5 minutes while
supplying full rated VA output power. Output voltage under this condition 115 VAC +5% -7% |
| Input Voltage Protection: |
Inverter withstands transients of 88 volts lasting 1
mSec on the 28.0 VDC. |
| Overload & Short Circuit Protection: |
Withstand without damage or degradation loads exceeding
150% of rated output to an output short circuit. Inverter delivers rated output on removal
of above conditions. 200% output current for fault clearance. |
| Altitude: |
55,000 ft. |
| Humidity: |
Tested to greater than 95% for ten days, temperature
cycled between 75°F to 160°F. |
| Environmental: |
Qualified to meet RTCA DO-160 env. cat. D2BR---- |
| Mating Plug: |
MS3106A24-11S |
1. Total continuous output power is 750 VA |