| SPECIFICATIONS: |
|
| Input Voltage
(VDC): |
| 20 TO 36 VDC |
11 TO 16 VDC |
|
Input Current (ADC):
@ 28 VDC IN |
|
Output Power (Total):
115 VAC / 26 VAC |
50VA
50VA / 30VA |
50VA
50VA / 30VA |
|
| Efficiency (%) : |
|
| Output Voltage: |
115 VAC and / or 26 VAC |
| Phase/Waveform: |
Single / Sine Wave |
| Frequency: |
400 Hz ± 1% |
| Amplitude Distortion: |
Less than 7% (3%
Typ.) |
| Power Factor: |
.8 to -.95 |
| Weight: |
3.1 lbs. |
| Input
Overvoltage: |
Operate up to 37 VDC input while supplying full rated
VA output power. Output voltage under this condition is 115 VAC +5%, 7%. |
| Input Transient Protection: |
Withstands transients of 88 volts 1 mSec on the 28
VDC input line. |
| Overload & Short Circuit
Protection: |
Withstands without damage or degradation load
exceeding 150% of rated output to an output dead short.Inverter delivers rated output on
removal of above conditions. |
| Altitude: |
55,000 ft. |
| Temperature: |
-65°F to +160°F (-55°C to +71°C) |
| Humidity: |
Tested to greater than 95% for 10 days, temperature
was cycled between 75°F to 160°F |
| Environmental: |
Designed to meet RTCA paper DO-160 Env. Cat. D2BR--- |