TSO'D 400HZ  STATIC INVERTER
375 VA

The SPC-38( ) static inverter utilizes solid state circuitry to convert 28 VDC to 115 VAC, 400 Hz sine wave power. Design features include transformerless square to sine power conversion permitting light weight and reliable operation.

The SPC-38( ) is capable of delivering an overload of 150% of rated power for a duration not less than five minutes under all environmental conditions.



Model SPC-38(  )

Features:

  • Foldback current limit during overload.
  • 200% output current capability for fault clearance.
  • Remote on-off feature to eliminate the need for a heavy and expensive solenoid.
  • Shut down in the event of Low/Hi frequency and overvoltage malfunction.
  • Soft start logic in conjunction with step input and any restart after output short, output shutdown or remote off. Prevents inverter from drawing heavy surge current during start transition.
  • Fault monitor output for malfunction indication noted above.

Specifications:

 Input Voltage:  Nominal; 28.0 VDC ± 4 VDC
Range: 20 to 37 VDC
 Input Current:  16A @ full load
2A max @ no load
 Output Voltage:  -5% -7% (± 2% typ. on 115V)
 Output #1:  115 VAC (375 VA max. cont.)
 Output #2:  26 VA (75 VA max. cont.)
 Output Power:  375 VA Total max. cont.
(Sum of 115 and 26 VAC outputs)
 Output Frequency:  400 Hz ± 1%
 Phase & Waveform:  Single phase sine wave.
 Harmonic Distortion:  2.0% typ. (5% max.) 20 to 37 VDC in.
 Power Factor:  .8 to -.95
 Efficiency:  83% typical.
 Temperature:  -55°C to 71°C
 Weight:  8.0 lbs.
 Overload Capacity:  Capable of 150% output current @ normal AC output for 5 minutes.
 Input Overvoltage: Withstand 130% input overvoltage for 5 minutes while supplying full rated VA output power. Output voltage under this condition 115 VAC +5% -7%
 Input Voltage Protection:  Inverter withstands transients of 88 volts lasting 1 mSec on the 28.0 VDC input line.
 Overload & Output Short Circuit Protection:  Withstand without damage or degradation loads exceeding 150% of rated output to an output short circuit. Inverter delivers rated output on removal of above conditions. 200% output current for fault clearance.
 Altitude:  55,000 ft.
 Humidity:  Tested to greater than 95% for ten days, temperature cycled between 75°F to 160°F.
 Environmental:  Qualified to meet RTCA DO-160 env. cat. D2BR----

1. Total continuous output power is 375 VA

 

  MODEL  OUTPUT VOLTAGE  OUTPUT POWER VA  CONNECTOR PLUG  INPUT VOLTAGE RANGE  WEIGHT LBS. (KG.)
 SPC-38( ) 26/115 VAC  75/375 (1) MS3106B18-9S  20-37  8.5 (3.8 kg.)
 SPC-38(A)  26/115 VAC 75/375 (1)  MS3106B18-9SW   20-37 8.5 (3.8 kg.) 
 SPC-38(B) 26/115 VAC  75/375 (1)   MS3106B18-9SW  20-37 8.5 (3.8 kg.) 
 SPC-38(T) 26/115 VAC  75/375 (1)  MS3106B18-9S   16-32 8.5 (3.8 kg.) 


Home | About us | AC to DC Power Supplies | DC Power Converters TSO'd | Static Inverters 400 Hz TSO'd | Static Inverters 60 Hz TSO'd | E/L Panel Inverters
Frequency Converters 60/50 Hz SINE Wave TSO'd | 400 Hz Freq Changers | Other Products | Product Map | Catalog Request | Customer Feedback | Service |
Sales Information
| Certifications | Gallery | Whats New | Contact us


KGS Electronics
418 East Live Oak Ave
Arcadia, CA 91006-5619 (USA)
Phone: 626-574-1175
Fax: 626-574-0553

info@kgselectronics.com