SPECIFICATIONS |
| Input Voltage: |
28 Vdc NOM., 24 to 32 Vdc |
|
|
18 Vdc to 36.4 Vdc (Abnormal
Range) |
| Input Current: |
1.35 Amps typ at 28 Vdc input
at FL |
|
|
0.6 Amps maximum at no load |
| Output Voltage: |
SC3: 115 Vac
SC3(A): 26Vac |
| Output Current: |
SC3: .26 Amps continuous
SC3(A): 1.15 Amps Continuous |
| Frequency: |
400 Hz ± 1% |
| Distortion
(THD): |
3% typical at FL (unity pf)
at 28 Vdc 7% maximum for the input range & pf |
| Isolation: |
Output is isolated from input |
| Power |
30 VA maximum |
| Power Factor: |
.95 leading to .8 lagging
power factor |
| Regulation: |
3% for load, 2% for line and
3% for temperature |
| Overload(OL): |
Deliver 150% output current
for 5 min. |
| Protection(OL): |
Withstands without damage or
degradation load exceeding 150% to an output short circuit. Unit delivers rated output
power upon removal of the overload condition |
| Protection(SC): |
Under a output short circuit
condition, the input current folds back and the output current is limited to a safe value |
| Protection(OV): |
Output voltage is limited to
145 Vac maximum |
| Soft-Start: |
Minimum soft start delay of
100 mSec at full load is provided during an application of step input voltage to reduce
output in rush current. |
| Shutdown(SD): |
Output shuts down when input
voltage is below 14 Vdc and above 36.4 Vdc. |
| Temperature: |
-55° C to +71° C |
| Altitude: |
55,000FT |
| Compliance: |
FAA TSO-C73 |
| Connector: |
Unit mates with MS3106A14-6S |
| Finish: |
Gold iridite per MIL-C-5541
Class 1A |
| Weight: |
1 LBS (454 grams) |
| Size: |
2.00 H x 3.18 W x 5.00 L
inches
50.8 H x 80.8 W x 127.0 L mm
(Less protrusion of connector
and screw heads) |