| Input Voltage: |
Normal: 12 to
28 Vdc Abnormal: 8 to 36Vdc |
| Input Current: |
21.8 Amps typ at 14
Vdc input
& @FL (0.5 Amps maximum at no load) |
| Overload: |
Unit will not suffer damage or degradation in
performance from an overload input current of 50 Amps for 5 Sec or
until a 25 Amp input circuit beaker trips |
| Output Voltage: |
28 ± 0.5 Vdc regulated for input voltage from 8 to 28
Vdc (Switching Mode)
Follows input voltage for the input above 28 Vdc
(Override Mode) |
| Output Current: |
0-10 Amps continuous.
15 amps for 5 minute. |
| Power: |
280 Watts continuous for input voltage from 12 to
28 Vdc.
420 Watts for 5 minutes at 14 Vdc input
voltage |
| Regulation: |
1% for line, 1% for
load and 1%
for temperature |
| Overload
(OL): |
Delivers 110% output power for
2 hours minimum |
| Protection
(OL): |
|
| Protection (SC): |
Unit is protected against output short circuit by
an external 25 Amp input circuit breaker per MIL-C-5809 |
| Efficiency: |
92% typical |
| Temperature: |
-55° C to +71° C |
| Altitude: |
55,000FT |
| Compliance: |
FAA TSO-C71 |
| Environmental: |
DO-160D/C test, design similarity and/or
design analysis:
F2-BBB[STX]EWXDFSABAZZXLXXXX |
| Weight: |
1.3 lbs. |
| Size: |
2.75 W x 6.875 L x 2.24 H
inches
Less protrusion of connector
69.9 W x 174.6 L x 56.9 H mm
and screw heads |
| Cooling: |
Convection and thermal conduction through the
bottom plate (No internal fan) |
| Finish: |
Gold iridite per MIL-C-5541 Class
1A |