| Input Voltage: |
28 Vdc NOM., 22 to
32 Vdc |
| Input Current: |
23 Amps typ at 28 Vdc input
& @FL |
| |
0.5 Amps maximum at no load |
| Output Voltage: |
14 Vdc regulated |
| Output Current: |
0-40 Amps continuous |
| Regulation: |
5% for load, .5% for line and
3%
for temperature |
| Overload
(OL): |
Deliver 110% output power for
2 hours |
| Protection
(OL): |
Withstands without damage or
degradation load exceeding 150% to an output short circuit. Unit delivers rated output
power upon removal of the overload condition |
| Protection (SC): |
Under a output short circuit
condition, the current is limited to approximately 40 Amps |
| Efficiency: |
90% typical |
| Temperature: |
-55° C to +71° C |
| Cooling: |
Convection and thermal conduction through the
bottom plate (No internal fan) |
| Altitude: |
55,000FT |
| Compliance: |
Designed to meet FAA TSO-C71 |
| Environmental: |
DO-160D/C by test, design similarity and/or
design analysis per:
F2VBBB[STX]EWXDFSABAZZXL[XXC1]XXA |
| Finish: |
Gold iridite per MIL-C-5541 Class
1A |
| Weight: |
2.5 lbs. (1.1 kg) |
| Size: |
4.30 W x 6.88 L x 2.75 H
inches
Less protrusion of connector and
109.2 W x 174.7 L x 69.9 H mm screw heads |