| Input Voltage: |
28 Vdc NOM., 22 to
32 Vdc |
| Input Current: |
10.8 Amps typ at 28 Vdc input
& @FL |
| |
0.3 Amps maximum at no load |
| Output Voltage: |
14 Vdc regulated |
| Output Current: |
0-20 Amps continuous |
| Power Output: |
280 Watts
continuous
420 Watts for a minimum of 5 minutes |
| Regulation: |
1% for line, 1% for
load and 1%
for temperature |
| Overload
(OL): |
Deliver 110% output power for
2 hours minimum. |
| Protection
(OL): |
Withstands without damage or
degradation loads exceeding 110% to an output short circuit. Unit delivers rated output
power upon removal of the overload condition |
| Protection (SC): |
Under a output short circuit
condition, the current is limited to approximately 37.5 Amps |
| Efficiency: |
92% typical |
| Temperature: |
-55° C to +71° C |
| Cooling: |
Convection and thermal conduction through the
bottom plate (No internal fan) |
| Altitude: |
55,000FT |
| Compliance: |
FAA TSO-C71 |
| Environmental: |
DO-160D/C by test, design similarity and/or
design analysis per:
F2-BBB[STX]EWXDFSABAZZXLXXXX |
| Finish: |
Gold iridite per MIL-C-5541 Class
1A |
| Weight: |
1.2 lbs. |
| Size: |
2.75 W x 6.875 L x 2.24 H
inches
Less protrusion of connector
69.9 W x 174.6 L x 56.9 H mm
and screw heads |