| Specifications: |
| Input
Voltage: |
115 Vac, 47 Hz to 440
Hz |
| Normal: |
105 Vac to 125 Vac |
| Abnormal: |
95 Vac to 130 Vac |
| Input
Current: |
0.23 Amps typical at
115 Vac & at FL |
| Output
Voltage: |
7.5 Vdc regulated
(Factory set) |
| Output
Current: |
1.34 Amps continuous |
|
1.50 Amps
intermittent |
| Regulation: |
3% for load, 1% for
line and 3% for temperature |
| Isolation: |
DC output is isolated
from input and AC input is isolated from chassis GND. |
| Ripple/Spike: |
71 Vrms maximum |
| Overload(OL): |
Deliver 110% output
power for 2 hours |
| Protection(OL): |
Withstands without
damage or degradation load exceeding 110% to an output short circuit. Unit delivers rated
output power upon removal of the overload condition |
| Protection(SC): |
Under a output short
circuit condition, the input and output currents pump and the currents are limited to safe
values. |
| Temperature: |
-40° C to +71° C |
| Altitude: |
55,000FT |
| Connector: |
Unit mates with
MS3126F14-5S |
| Finish: |
Gold iridite per
MIL-C-5541 & black paint |
| Weight: |
.50 LBS (227 grams) |
| Size: |
1.56 H x 2.00 W x
5.00 L inches |
|
39.6 H x 50.8 W x
127.0 L mm |
|
Less protrusion of
connector and screw
heads |