| Specifications: |
| Input Voltage: |
28 Vdc NOM., 22 to 36 Vdc |
| Input Current: |
3.4 Amps typ at 28 Vdc input
and full load |
| |
5.2 Amps maximum at
18Vdc input and full load |
| Output Voltage: |
#1: 0-5 Vdc regulated
#2: 5 Vdc fixed regulated |
| Output Current: |
#1: 0- 7.5 Amps continuous
#2: 7.5 Amps continuous |
| Regulation: |
2% for load, 2% for line and
2%
for temperature |
| Ripple: |
10 mVpp typ at 25c,
25mVpp maximum |
| Overload(OL): |
Deliver 110% output power for 2
hours |
| Protection(OL): |
Withstands without damage or
degradation load exceeding 110% to an output short circuit. Unit delivers rated output
power upon removal of the overload condition |
| Protection(SC): |
Under a output short circuit
condition, the input current folds back and the output current is limited to a safe value |
| Protection(OV): |
Output voltage is limited to
approx 130% of rating even though the remote rheostat opens or shorts for
output #1 or certain types of internal failure. |
| Reverse Polarity: |
A reverse polarity
diode is placed across the input to trip a MIL-C-6809 5 amp circuit
breaker in the event of input reverse polarity. |
| Efficiency: |
75% typical |
| Temperature: |
-55° C to +71° C |
| Altitude: |
55,000FT |
| Compliance: |
FAA TSO-C71 |
| Environmental: |
DO-160C
ENV. CAT
F2ZBB(MLV)XXXDFSAAAXXXZKXX |
| Connector: |
Unit mates with
KPTO6A14-5S(SR) |
| Finish: |
Gold iridite per MIL-C-5541 Class
1A |
| Weight: |
1.2 LBS (544 grams) |
| Size: |
1.65 H x 4.00 W x
5.03 L inches (Less protrusion of connector and screw heads)
4.1 H x 5.1 W x 12.8 L cm |