TSOD 50/60 Hz
AC
Frequency Converters |
2 KVA SINEWAVE |
Description:
The HS200 & HB200 are
highly efficient, lightweight AC frequency power converters. These models utilize the latest state
of the art solid state circuitry to convert a 115/200 Vac, 400 Hz, 3 PH input to 115 Vac,
60 Hz or 230 Vac, 50 Hz sine wave output.
Design
features include a crystal-controlled oscillator for
output frequency stability and a pulse-width-modulated
square to sine wave power conversion scheme for
efficient and reliable operation.
|
 |
The
HS200 and HB200 static frequency changers are designed
to power laptop computers, audio/video entertainment
systems, portable electronics (stereo, MP3, CD, DVD,
video games, etc.), microwave ovens, coffee makers and
medical equipment in airborne, marine and ground
mobile applications.
|
| Specifications: |
| Input Voltage: |
115/200 Vac ± 10 Vac |
| Input Frequency: |
400 Hz ± 200 Hz |
| Model: |
HS200 |
HB200 |
| Output Voltage: |
115 Vac
(108 to 120 Vac) |
230 Vac (216 to
240 Vac) |
| Output Frequency: |
60
HZ (± 0.1 Hz) |
50 HZ (± 0.1
Hz) |
| Output Wave Form: |
Sine |
| Harmonic Distortion: |
0.5 % (nominal) |
| Power Factor: |
+0.8 TO -0.8 |
| Output Phase: |
Single |
| Efficiency: |
87 % (nominal) |
| Response Time: |
300 uSec (No Load to
Full Load) |
| Regulation: |
1 % Line, 1 % Load,
2.5 % Temperature |
| Overload Capacity: |
110 % of rated power
for 2 hrs, 150 % of rated power for 5 minutes |
| Protection Circuit: |
The inverter will
shutdown under the following conditions:
- Input voltage >137 ± 5Vac.
- Input voltage < 80Vac ± 20Vac.
- Internal high ambient temperature.
- Short circuit condition (after 2 to 15 Sec)(manual reset)
|
| Remote On/Off |
Yes |
| Operating Temperature: |
-55 ° C to +71 ° C
(-65 ° F to +160 ° F) |
| Altitude: |
55,000 ft |
| Environmental: |
RTCA DO-160C Env.
Cat. F3ZBB[ LV] E1XXXXXBXAXXXBXXX |
| Cooling: |
Thermostatically
controlled brushless fan (ON above 50 ° C) |
| Weight: |
17.7 lbs (8.04
kgs) |
| Compliance: |
FAA TSO-C73 |
|
|
|