| Specifications: |
| Input Voltage: |
115 Vac 400 Hz nom., 105 to 125 Vac |
| |
95 Vac to 130 Vac (Abnormal Range) |
| Input Current: |
2.8 Amps typ @ FL & at 115 V input |
| Output Voltage: |
0-5 Vac 400 Hz regulated |
| Output Current: |
0-40 Amps continuous |
| Frequency: |
400 Hz ± 2% |
| Distortion
(THD): |
7% max at full load & at 115 Vac input |
| Power: |
200 Watts |
| Power Factor: |
Unity (resistive) |
| Overload(
OL): |
150% output current for 5 min. |
| Protection
(OL): |
Withstands without damage or degradation load
exceeding 150% to an output short circuit. Unit delivers rated output power upon removal
of the overload condition |
| Regulation: |
7% for load, 2% for line and 3% for
temperature |
| Isolation: |
Output is isolated from input |
| Control: |
Output 0-5 Vac is controlled by a 0-5 Vdc
voltage from the slider of an external 10K ohm pot or directly from a 0-5 Vdc voltage
source |
| Protection (SC): |
Under a output short circuit condition, the
input current folds back and the output current is limited to a safe value |
| Protection
(OV): |
Output voltage is limited to 145 Vac maximum |
| Soft-Start: |
Minimum soft start delay of 100 mSec at full
load is provided during an application of step input voltage to reduce output in rush
current to the load. |
| Shutdown (SD): |
Output shuts down when input voltage is below
95(±10) Vac and above 135(±10) Vac |
| Temperature: |
-55°C to +71 °C |
| Altitude: |
55,000FT |
| Connector: |
Mates with MS3106A28-9S |
| Finish: |
Gold iridite per MIL-C-5541 Class 1A |
| Weight: |
5.3 LBS (2.4 kg) |
| Size: |
4.60 H x 4.42 W x 6.47 L inches |
| |
116.8H x 112.3 W x 164.3 L mm |
| |
Less protrusion of connector and screw heads |