SPECIFICATIONS:
|
| |
Input Voltage: |
120
Vac ± 10 % (108 to 132 Vac) |
|
Input Frequency: |
47
to 440 Hz
|
OUTPUT:
|
|
Voltages: |
0
to 130 VAC and 0 to 30 VAC |
Current:
|
10
Amp for 0 to 130 VAC and
5.77 Amp for 0 to 30 VAC |
Crest
Factor:
|
3:1
|
|
Power
Factor:
|
100%
of rated output into any power factor
|
Distortion:
|
1%
THD typical at full linear load |
Load Regulation: |
±
1% No load to Full load
|
Line
Regulation:
|
± 0.1% for ± 10% line change |
Efficiency:
|
80
to 85 % |
|
|
PROTECTION CIRCUIT: |
Input:
|
Fuse |
Over
Current:
|
Voltage
foldback |
Short
Circuit:
|
Latches
off to protect load. Recycle input power to restore |
Thermal:
|
Over
temperature shutdown.
|
26
VAC:
|
6
Amp fuse on rear panel
|
Operating
Temperature:
|
0°C To 55°C
|
|
FRONT
PANEL METER & CONTROLS: |
|
Power
On/Off switch:
|
|
Voltage
and Frequency Potentiometers
|
Two
digital meters: True RMS Volts, True RMS Amps or Frequency.
|
Frequency
/ Amps select switch and indicator
|
Output
On/Off switch & indicator
|
Two
LED’s: Constant current and fault output
|
Safety
socket
|
|
MECHANICAL: |
Dimensions:
|
3.5”
H x 17” W x 17” D for
19” relay rack mounting |
Weight:
|
39
lbs |
Input
Connection:
|
IEC
320 C-20 receptacle with 6 foot line cord with NEMA5-15 plug. |
Output
Connection:
|
Rear
mounted barrier strip & Front panel safety socket (banana
receptacle) |
Cooling:
|
Internal
fans w/side intake and rear exhaust |