| Specifications: |
| Input Voltage: |
115 Vac 400 Hz nom., 105 to 125 Vac |
| |
95 Vac to 130 Vac (Abnormal Range) |
| Input Current: |
.73 Amps typ at 150VA EL load at 115V |
| Output Voltage: |
0-115 Vac 400 Hz regulated |
| Output Current: |
0-1.3 Amps continuous |
| Power: |
150 VA |
| Power Factor: |
Zero to -0.2 leading (capacitive) |
| Frequency: |
400 Hz ± 2% |
| Distortion: |
3% typ at 75VA & 7% typ at 150VA |
| Regulation: |
7% for load, 3% for line and 3% for temperature |
| Isolation: |
The output is isolated from the input |
| Control: |
Output 0-115 Vac is controlled by a 0-5 Vdc voltage from the
slider of an external 10K ohm pot or directly from a 0-5 Vdc voltage source |
| Overload(OL): |
150% output power for 5 min. |
| Protection(OL): |
Withstands without damage or degradation a |
| |
load exceeding 150°/O (-.2pf) to an output short |
| |
circuit. Unit delivers rated output power upon |
| |
removal of the overload condition |
| Protection(SC): |
Under a output short circuit condition, the input current
folds back and the output current is limited to a safe value |
| Protection(OV): |
Output voltage is limited to 145 Vac maximum |
| Soft-start: |
Minimum soft start delay of 100 mSec at full load is provided
during an application of step input voltage to reduce output in rush current to the EL
panel. |
| Shutdown(SD): |
Output shuts down when the voltage is below 95(±10) Vac and
above 135(±10) Vac |
| Temperature: |
-55°C to +71 °C |
| Altitude: |
55,000FT |
| Connector: |
Mates with MS3106A16S-1 S |
| Finish: |
Gold iridite per MIL-C-5541 Class 1A |
| Weight: |
5.1 LBS (2.3 kg) |
| Size: |
3.90 H x 4.38 W x 8.50 L inches |
| |
99.0 H x 111 W x 216L mm |
| |
Less protrusion of connector and screw heads |