| Specifications: |
| Input Voltage: |
28
Vdc NOM., 18 to 32 Vdc
|
| Output Voltage: |
CH1: 0-5 Vdc / 0-20 Amp (100 W)
CH2: 0-28 Vdc / 0-4.3 Amp (120 W)
CH3: 0-115 Vac / 0-1.04 A (120 VA) to
EL panel (0.2 leading pf load) |
| Frequency: |
CH3: 400 (±10)
Hz |
| Wave
Form: |
CH3: Sine wave, single phase |
| Distortion
(THD): |
CH3: 10% at 28Vdc at rated .2 pf load |
| Regulation: |
CH1: 3% load, 2% line & 3% for temp.
CH2: 3%
load, 2% line & 3% for temp.
CH3:
10%
load, 2% line & 3% for temp. |
| Soft
Start: |
Minimum
soft start delay of 200 mSec at full load is provided during an
application of step input voltage to reduce output in-rush current. |
| Overload
(OL): |
Deliver
110% output power for 2 hours |
| Protection
(OL): |
Withstands
without damage or degradation load exceeding 110% to an output short
circuit. Unit delivers rated
output power upon removal of the overload condition |
| Protection
(SC): |
Under
a output short circuit condition, the input current folds back and the
output current is limited to a safe value |
| Protection
(OV): |
Output
voltage is limited to 125% max |
| Shutdown
(SD): |
Output
shuts down when input voltage is below 13 Vdc and above 36±2
Vdc |
| Thermal
(SD): |
Shuts
down when air temperature inside unit reaches 105(±5)°C |
| Protection(OL): |
Withstands without damage or degradation a |
| Cooling: |
Thermostatically
controlled fan at 60°C |
| Temperature: |
-55°C to +71 °C |
| Altitude: |
55,000FT |
| Compliance: |
FAA
TSO-C73 |
| Environment: |
MIL-STD-810C/D
& MIL-STD-108E |
| EMI/EMC: |
MIL-STD-461B |
| Connector
Mating: |
M83723/77R2025N |
| Finish: |
Gold iridite per MIL-C-5541 Class 1A |
| Weight: |
4.8
LBS (2.18 kgrams) |
| Size: |
2.50
H x 6.50 W x 9.60 L inches
63.5
H x 165.1 W x 243.8 L mm
Less protrusion of connector and screw heads |