TSO'D 250 VA THREE PHASE STATIC INVERTER
| The SE25 is primarily designed to power 115 VAC line to
neutral or line to line 400 Hz three phase Wye or Delta system loads with maximum
continuous output power of 250 VA. SE25 inverter applications include airborne or ground
instruments, navigation equipment and radar systems. The SE25 operates from a 28 VDC source and the output can be configured for three wire 115 volt delta load, or four wire 115/200 volt wye loads. Each AC output phase (ØA, ØB & ØC) is isolated from the DC input and chassis ground. The SE25 is interchangeable dimensionally with 250 VA inverters conforming to MS21983-3. |
|
Specifications: |
|
| Input Voltage: | 28 VDC ± 4 VDC, |
| Current: | 10.7 amps typ. at 28 VDC / 85 VA load per phase. 1.1A max at no load. |
| Output Voltage: | 3 Wire Delta: 115Vrms ± 3% line to line or, 4 Wire Wye: |
| Load Unbalance: | Maximum load unbalance is 20% for specification performance. |
| Current: |
|
| Power: | 85 VA per phase, 250 VA total |
| Phase Angle: | 120° ± 5° |
| Frequency: | 400 Hz ± 1% |
| Waveform: | Sine wave/three phase Ø configuration |
| Power Factor: | .8 lagging to .95 leading power factor |
| Distortion: | 7% maximum (3.0% typ at 28 VDC in) |
| Overload (OL): | 150% output current for at least 5 min |
| Short Circuit: | 200% output current for 1 min. |
| Soft Start: | Soft start delay of approximately 500 mSec. |
| Reverse Polarity: | The inverter is protected against reverse polarity applied at the input |
| Efficiency: | 81% minimum. |
| Temperature: | -65°F to +185°F (-55°C to +85°C) |
| Altitude: | 75,000 ft. |
| Weight: | 8.4 lbs. (3.81 kg.) |
| Environmental: | Designed to FAA TSO-C73 Appendix A and DO-160C env. cat. F2WBBTEWXDFSAAAZZUZKXX |
| Compliance: | FAA TSO-C73. Interchangeable dimensionally with 250 VA units conforming to MS21983-3. |
| KGS Electronics Home | On-line Catalog | Service Centers |
| Catalog Request | info@kgselectronics.com | Contact Information |